Home / Metal Detectable Blue FDA Neoprene
placeholder-image

Item Code: SM168

Metal Detectable Blue FDA Neoprene

Propertiestest method
values
fps units
test method
values
metric units
Specific GravityDIN 535081.50 ± 0.05ASTM D2971.50 ± 0.05
HARDNESSDIN 5350565 ± 5 Sh AASTM D224065 ± 5 Sh A
TENSILE STRENGTH ( min )DIN 535041990PSIASTM D412140 kg/cm2
ELONGATION AT BREAK ( min )DIN 53504600%ASTM D412600%
COMPRESSION SET (70ºC/24 hrs/25% set) (max)DIN 5351750%ASTM D395 METHOD B50%
Polymer Content (%)100100
TEAR RESISTANCE ( Angular ) minDIN 53515170 Lbs/InchASTM D62430 Kg/cm
CHANGE IN PROPERTIES AFTER
HEAT AGEING ( 72 hrs. AT 70 ºC )ASTM D573
--- HARDNESS (Pts)+ 5 (Max)+ 5 (Max)
--- TENSILE STRENGTH (%)+ 10 / - 25+ 10 / - 25
--- ELONGATION AT BREAK (%)+ 10 / - 30+ 10 / - 30
VOLUME SWELL : AT 70ºC FOR 72 HRS/INASTM D 471
IRM OIL NO.1+18%+18%
IRM OIL NO.2+23%+23%
IRM OIL NO.3+60%+60%
POLYMER CONTENT (NEOPRENE)100%100%
CHEMICAL RESISTANCE
--- OZONEGOODASTM D 1149GOOD
--- DILUTE ACIDS AND BASESGOODGOOD
--- CONCENTRATED ACIDS AND BASESFAIRFAIR
--- OILSGOODGOOD
--- SOLVENTSFAIRFAIR
TEMPERATURE RANGE-25º to + 120º C-25º to + 120º C
COLOURBLUEBLUE

RELATED PRODUCTS

Consent

I agree to my personal data being stored and used to receive the newsletter.

This website uses cookies. If you agree to our Privacy & Cookies Policy, please click here