Vacuum White FDA/EU1935 EPDM – Approved to: FDA 21 CFR No: 177.2600

SKU: SM258
Roll Size: 10m

This product is available for bespoke manufacturing, please choose an option below:

Select Options

• Approved to FDA 21 CFR 177.2600 and EU1935/2004 compliant
• BSE & TSE Free and non-toxic
• REACH, RoHS, PAH and CE compliant

PROPERTIES

TEST METHOD

VALUES FPS UNITS

TEST METHOD

VALUES METRIC UNITS

SPECIFIC GRAVITY DIN 53508 1.4 ± 0.5 ASTM D297 1.4 ± 0.5
HARDNESS DIN 53505 57 ± 5 SH A ASTM D2240 57 ± 5 SH A
TENSILE STRENGTH ( MIN ) DIN 53504 50 KG/CM2 ASTM D412 711 PSI
ELONGATION AT BREAK ( MIN ) DIN 53504 600% ASTM D412 600%
COMPRESSION SET (70ºC/24 HRS/25% SET) (MAX) DIN 53517 40% ASTM D395 METHOD B 40%
TEAR RESISTANCE ( ANGULAR ) MIN DIN 53515 101 LBS/INCH ASTM D624 18 KG/CM
CHANGE IN PROPERTIES AFTER
HEAT AGEING ( 72 HRS. AT 70 ºC ) ASTM D573
— HARDNESS (PTS) + 5 (MAX) + 5 (MAX)
— TENSILE STRENGTH (%) + 10/ – 10 + 10/ – 10
— ELONGATION AT BREAK (%) + 10/ – 10 + 10/ – 10
POLYMER CONTENT (EPDM) 100% 100%
CHEMICAL RESISTANCE
— OZONE EXCELLENT ASTM D 1149 EXCELLENT
— DILUTE ACIDS AND BASES EXCELLENT EXCELLENT
— CONCENTRATED ACIDS AND BASES EXCELLENT EXCELLENT
— OILS EXCELLENT EXCELLENT
— SOLVENTS NOT RECOMMENDED NOT RECOMMENDED
TEMPERATURE RANGE -25º TO + 140º C -25º TO + 140º C
COLOUR WHITE

 

Test Name – Determination of Amount of extractives Method: With reference to US FDA 21 CFR 177.2600

Extractants

Test Condition

Amount of Extractives mg/inch²

Acceptable Limit mg/inch²

Conclusion

1

Distilled Water

70 °C for 2 hours

10

20

Pass

n-Hexane

70 °C for 2 hours

100

175

Pass

Note:

  1. mg/inch2 denotes Milligram per square inch
  2. °C denotes Degrees Celsius

 