Property

Standard

Units

Standard

Description

Light Transmittance ASTM D 1003 % 85 Visible light rate transmitted through the material.
Shore A Hardness EN ISO 868 Sh A 62 Index based on a flat indenter’s penetration depth. Scale from 0 (Soft) to 100 (Hard)
Tearing Resistance DIN 53515 N/mm 25 Minimum tensile stress required to tear a pre-slit sample.
Tensile Strength At Break ASTM D 638

EN ISO 527

N/mm2 10 Maximum tensile stress that a material can be subjected to before break.
Elongation At Break % 420 Elongation of the specimen at the break point under tensile stress.
Residual Elong. (After Break) % 80 Permanent elongation of the specimen measured after rupture in a tensile test
Thermal Conductivity ASTM C 177 W/m.k 0.16 Ability to conduct heat. The lower it is, the more insulation.
Cold Bend Brittle Temp. ISO 8570 ºC -65 Temperature at which the specimen breaks under torsion stress. Brittle point (Clash-Berg)
Min. Usage Temp EN 1876 ºC -60 Temperature range where material keeps its mechanical properties (flexibility).
Max. Usage Temp ºC +15
Vicat Softening Temp. EN ISO 306 ºC 46 Temperature at which the specimen is penetrated to a depth of 1mm by a 1kg flat indenter of 1sq. mm.
Specific Heat Capacity ISO 11357 kJ/kg.K 1.6 Heat energy required to increase the temperature of one kilogram of the material by one degree Celsius.
Sound Reduction DIN 52210 dB >35 Average sound level (freq. 0.1 to 3.2kHz) decreased by a 1.76sq.m. and 5mm thick PVC curtain.
Reaction To Fire EN 13501-1:2007 Class Standard classifications of material self-extinguishing and resistance to combustion.
UV/IR Filter EN 1598 & ISO 25980 Ability to filter welding rays allowing the use of this material as a welding protection screen.
UV Resistance ISO 4892 Yes Ability to resist to UV (Sun, welding arc).
Surface Resistivity ASTM D257 1010 Ω/sq 3 Material surface electric resistivity measured with a 100V direct voltage.
Water Absorption EN ISO 62 % -0.2 Material mass variation after exposure to humid conditions. (<0 if released / >0 if absorbed)
Anti-Insect No Special ability to keep insects away. (Food processing plants, tropical regions)
Density ASTM D 792 g/cm³ 1.18 Mass per unit volume.