Duro-Tranz Fire Retardant Transit Floor Coverings

SKU: Duro-Tranz
Roll Size: 10m

Select Options

  • Manufactured as per specification EN 45545 R 10 HL 2/ HL3, International Maritime Organization (IMO)
  • Halogen Free Floorings, technical floorings for fire resistance & smoke toxicity
  • LSOH (Low Smoke Zero Halogen)
  • Tested by Warrington Fire U.K, LAPI Italy
  • Manufacturing Capacity – 50, 000 m2 per month
  • Available in 2mm-6mm thicknesses
  • Available in 1m, 1.2m, 1.4m, 1.5m, 1.8m and 2m widths
  • Available in rolls from 10m to 30m
  • Available in multiple colours (see below)
PRODUCT DIMENSIONS
Code Thickness (mm) Width (meter) Length (meter)
Duro-Tranz Marbles 2 mm to 4.5 mm 1/1.2/1.4/1.5/1.8/2 10 to 30
Duro-Tranz Speckles 2 mm to 4.5 mm 1/1.2/1.4/1.5/1.8/2 10 to 30
Duro-Tranz Solids 2 mm to 4.5 mm 1/1.2/1.4/1.5/1.8/2 10 to 30
Duro-Tranz Ribbed Marbles 4.30 mm to 6 mm 1/1.2/1.4/1.5 10 to 30
Duro-Tranz Ribbed Speckles 4.30 mm to 6 mm 1/1.2/1.4/1.5 10 to 30
Duro-Tranz Ribbed Solids 4.30 mm to 6 mm 1/1.2/1.4/1.5 10 to 30

 

Warrington Fire Test for Determination of the Burning Behaviour of Floorings.

Part 1 Determination of the Burning Behaviour Using a Radiant Heat Source.

BS EN ISO 9239-1 2010

Objective: To Determine the performance of the following product when tested in accordance with BS EN ISO 9293-1: 2010.

 

GENERIC DESCRIPTION PRODUCT REFERENCE THICKNESS WEIGHT PER UNIT

AREA OR DENSITY

Rubberised floor covering

For use in railway coaches

& metro coaches adhered

to a birch plywood

substrate

“ICF/MD/SPEC-354”

(Flooring Only)

14.89mm* 9.80kg/m²*
Individual Components used to manufacture composite
Rubber Flooring “ICF/MD/SPEC-354” 2mm 2.5-3.4kg/m²
Adhesive “Adhesive Fevicol SR 998 IS

& Fevicol Hardner C”

Unwilling to provide Unwilling to provide
Plywood “Birch Plywood (WBP grade)” 12mm Unable to provide
*determined by Warrington Fire

 

Test Results:

Orientation of test specimens:                  No Direction

Average critical radiant flux        =             8.05W/M²

Average smoke development      =             28.92% Min

 

 

Warrington Fire Test for Determination of the Burning Behaviour of Floorings.

Part 2 Determination of Optical Density by a Chamber Method and “T11:02” ( Gas Analysis in the Smoke Box ISO, Using FTIR Technique).

EN 45545-2: 2013 + A1: 2015

Objective: To Assess the results of tests performed in accordance with methods T04, T10.03 and T11.02 as defined in EN45545-2: 2013 + A1:2015 at and irradiance level of 25W/m² with a pilot flame, on specimens of a product and to provide and opinion of compliance with the requirements, as defined in EN 45545-2: 2013 + A1: 2015.

 

GENERIC DESCRIPTION PRODUCT REFERENCE THICKNESS WEIGHT PER UNIT

AREA OR DENSITY

Rubberised floor covering

For use in railway coaches

& metro coaches adhered

to a birch plywood

substrate

“ICF/MD/SPEC-354”

(Flooring Only)

14.89mm* 9.80kg/m²*
Individual Components used to manufacture composite
Rubber Flooring “ICF/MD/SPEC-354” 2mm 2.5-3.4kg/m²
Adhesive “Adhesive Fevicol SR 998 IS

& Fevicol Hardner C”

Unwilling to provide Unwilling to provide
Plywood “Birch Plywood (WBP grade)” 12mm Unable to provide
*determined by Warrington Fire

 

Opinion: We consider the results of the tests confirmed in reports referenced 413221 and 413222 to the test methods detailed above demonstrate that the product as tested, complies with requirements, R10 ( detailed in table 5 of EN 45545-2: 2013 + A1: 2005) for a HL1, HL2 and HL3 hazard level classification.

 

 

Warrington Fire Test for Determination of the Burning Behaviour of Floorings

Part 2 Determination of Optical Density by a Chamber Method and “T11:02” ( Gas Analysis in the Smoke Box ISO, Using FTIR Technique).

EN 45545-2: 2013 + A1: 2015

Test Methods T10.03 & T11.02

Objective: To determine the toxic fume and optical density produced from the following product when tested in accordance with methods T10.03 and T11.02 as defined in BS EN 45545-2:2013 + A1: 2015 at an irradiance level of 25kW/M² with a plot flame.

 

GENERIC DESCRIPTION PRODUCT REFERENCE THICKNESS WEIGHT PER UNIT

AREA OR DENSITY

Rubberised floor covering

For use in railway coaches

& metro coaches adhered

to a birch plywood

substrate

“ICF/MD/SPEC-354”

(Flooring Only)

14.89mm* 9.80kg/m²*
Individual Components used to manufacture composite
Rubber Flooring “ICF/MD/SPEC-354” 2mm 2.5-3.4kg/m²
Adhesive “Adhesive Fevicol SR 998 IS

& Fevicol Hardner C”

Unwilling to provide Unwilling to provide
Plywood “Birch Plywood (WBP grade)” 12mm Unable to provide
*determined by Warrington Fire

 

Summary of Test Results:

The average Ds(max) value determined within 10 minutes was 137.

The average CIT value at four minutes was 0.10.

The average CIT value at eight minutes was 0.23.

 

Rubber Gaskets Quote Request

Cut Rubber Strips Quote Request

Cut Rubber Parts Quote Request