PHYSICAL PROPERTIES

TEST METHOD

SPECIFICATION OF METROLOAD BEARING PADS

Tensile Strength, Min ASTM D412 750 PSI
Tear Strength, Min ASTM D624 150 PI
Elongation, %, Min ASTM D412 15
Hardness, Shore A ASTM D2240 80 ± 5
Density (Relative) 1.23
Minimum Temperature ASTM D2137 -25°C
Maximum Temperature ASTM D2137 +120°C
Coefficient of Friction ASTM D1894 >0.8
Maximum Load (PSI) 1000
Abrasion Resistance 120mm3

STATIC STIFFNESS TEST RESULTS

TEST ITEMS TEST METHOD UNIT TEST RESULTS LIMIT EVALUATION
Static Stiffness BE EN 13146-9:2020 KN/mm 63.56 60±15% PASS

Note: The load range is 26KN to 76KN